Procedure of Retinoscopy


Introduction

Retinoscopy, also known as dynamic retinoscopy or objective refraction, is a technique used to determine the refractive error of the eye and prescribe corrective lenses. It is a quick and accurate method of measuring the refractive error of the eye, and is often used as a starting point for a comprehensive eye examination. In this article, we will discuss the process of retinoscopy and how it is used to determine the refractive error of the eye.

Equipment

The main piece of equipment used in retinoscopy is the retinoscope, which is a small, hand-held light source used to shine a beam of light into the eye. There are two types of retinoscopes: the streak retinoscope and the spot retinoscope. The streak retinoscope projects a thin beam of light into the eye, while the spot retinoscope projects a small, circular spot of light. The spot retinoscope is more commonly used for retinoscopy, as it allows for more precise measurement of the refractive error of the eye.

In addition to the retinoscope, other equipment used in retinoscopy may include a near target, such as a small card, and a distant target, such as a small light or the letters on a distant chart.

Examination procedure

The examination procedure for retinoscopy typically consists of the following steps:

  1. Patient preparation: The patient is asked to remove their glasses or contact lenses and to look at a distant target, such as a small light or the letters on a distant chart.
  2. Retinoscopy: The examiner holds the retinoscope in one hand and shines the light into the patient's eye. The reflection of the light from the retina is observed by the examiner, who uses this information to determine the refractive error of the eye.
  3. Determination of refractive error: To determine the refractive error of the eye, the examiner moves the retinoscope back and forth across the eye, observing the movement of the reflection. If the reflection moves in the same direction as the retinoscope, the eye is hypermetropic (farsighted). If the reflection moves in the opposite direction as the retinoscope, the eye is myopic (nearsighted). If the reflection remains stationary, the eye is emmetropic (normal vision).
  4. Measurement of accommodative response: The accommodative response is the ability of the eye to focus on objects at different distances. To measure the accommodative response, the examiner asks the patient to focus on a distant target, and then slowly brings a near target (such as a small card) closer to the eye. The examiner observes the movement of the reflection as the near target is brought closer to the eye, and uses this information to determine the accommodative response of the eye.
  5. Prescribing corrective lenses: Based on the results of the retinoscopy examination, the examiner will prescribe the appropriate corrective lenses for the patient.

Advantages and limitations

There are several advantages to using retinoscopy for the measurement of refractive error. One advantage is that it is a quick and easy technique that can be performed in a few minutes. It is also a relatively non-invasive method, as it does not require the use of drops or other medications. In addition, retinoscopy can be performed on patients of all ages, including children and infants.

However, there are also some limitations to retinoscopy. One limitation is that it is not as accurate as other methods of measuring refractive error